Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Imaging Inform Med ; 2024 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-38351220

RESUMO

Sensitive images represent a new challenge in enterprise imaging. These images, often containing nudity or gruesome content, have the potential to cause emotional harm to patients and people who view the images. Unfortunately, the interoperability standards used in imaging informatics have not yet addressed this issue. Because of this, the software solutions used in healthcare information technology are not able to offer patients and other viewers of image protections. In this Health Information Management Systems Society (HIMSS)/Society for Imaging Informatics in Medicine (SIIM) Enterprise Imaging Community Whitepaper, we define sensitive images, identify unique challenges related to their management, and provide recommendations for future solutions to protect our patients.

3.
Acad Radiol ; 31(3): 1130-1140, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37945493

RESUMO

RATIONALE AND OBJECTIVES: To evaluate wellness among interventional radiologists using a multidimensional survey. MATERIALS AND METHODS: An anonymous 53-item survey, including 36 Perceived Wellness Survey (PWS) prompts, was created in Qualtrics (an online survey tool) to assess wellness among interventional radiology attendings and residents. The survey was open from June to September, 2022, 2 years into the COVID-19 Pandemic. The survey was distributed via Society of Interventional Radiology Forums, social media (Twitter, LinkedIn, and Facebook), and personal correspondence. PWS scores were categorized into Wellness Composite and subscores (physical, emotional, intellectual, psychological, social, and spiritual). RESULTS: 367 surveys were completed. 300 (81.7%) respondents were male and 67 (18.3%) were female. Respondents included attending physicians (297; 81.0%) and residents (70; 19.0%). Practice settings included academic (174; 47.4%), private (114; 31.0%), private-academic hybrid (62; 16.9%), and others (17; 4.7%). Mean Wellness Composite at academic centers (14.74 ± 3.16; range: 5.42-23.50) was significantly lower than at private (15.22 ± 3.37; range: 6.13-23.51) and hybrid (16.14 ± 2.47; range: 10.20-23.50) practices (p = 0.01). Respondents < 40 years old had significantly lower emotional wellness subscores compared to those ≥ 40 years old (4.34 ± 0.86 vs. 4.60 ± 0.87; p = 0.006). There were no significant differences between geographic regions in the United States, however, International respondents had significantly lower social and intellectual wellness (INT) subscores. Physical wellness subscore (4.00 ± 0.9) was significantly lower than the other subscores (4.59 ± 0.81) (p < .001). Overall mean Wellness Composite was 15.11 ± 3.13 (range: 5.42-23.51). CONCLUSION: Overall self-reported wellness was lower among interventional radiologists practicing at academic centers. Interventional Radiologists < 40 years old and residents had lower emotional wellness, while international respondents had lower social and INT. Overall wellness scores were lower than prior PWS studies.


Assuntos
Esgotamento Profissional , COVID-19 , Humanos , Masculino , Feminino , Estados Unidos , Adulto , Pandemias , Inquéritos e Questionários , Radiologistas , Radiologia Intervencionista , Esgotamento Profissional/epidemiologia
4.
3D Print Med ; 9(1): 34, 2023 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-38032479

RESUMO

BACKGROUND: Medical three-dimensional (3D) printing has demonstrated utility and value in anatomic models for vascular conditions. A writing group composed of the Radiological Society of North America (RSNA) Special Interest Group on 3D Printing (3DPSIG) provides appropriateness recommendations for vascular 3D printing indications. METHODS: A structured literature search was conducted to identify all relevant articles using 3D printing technology associated with vascular indications. Each study was vetted by the authors and strength of evidence was assessed according to published appropriateness ratings. RESULTS: Evidence-based recommendations for when 3D printing is appropriate are provided for the following areas: aneurysm, dissection, extremity vascular disease, other arterial diseases, acute venous thromboembolic disease, venous disorders, lymphedema, congenital vascular malformations, vascular trauma, vascular tumors, visceral vasculature for surgical planning, dialysis access, vascular research/development and modeling, and other vasculopathy. Recommendations are provided in accordance with strength of evidence of publications corresponding to each vascular condition combined with expert opinion from members of the 3DPSIG. CONCLUSION: This consensus appropriateness ratings document, created by the members of the 3DPSIG, provides an updated reference for clinical standards of 3D printing for the care of patients with vascular conditions.

5.
3D Print Med ; 9(1): 8, 2023 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-36952139

RESUMO

The use of medical 3D printing has expanded dramatically for breast diseases. A writing group composed of the Radiological Society of North America (RSNA) Special Interest Group on 3D Printing (SIG) provides updated appropriateness criteria for breast 3D printing in various clinical scenarios. Evidence-based appropriateness criteria are provided for the following clinical scenarios: benign breast lesions and high-risk breast lesions, breast cancer, breast reconstruction, and breast radiation (treatment planning and radiation delivery).

9.
Acad Radiol ; 21(12): 1579-86, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25179562

RESUMO

RATIONALE AND OBJECTIVES: To understand the reasons leading to potentially inappropriate management of imaging findings concerning for malignancy and identify optimal methods for communicating these findings to providers. MATERIALS AND METHODS: We identified all abdominal imaging examinations with findings of possible cancer performed on six randomly selected days in August to December 2013. Electronic medical records (EMR) of one patient group were reviewed 3 months after the index examination to determine whether management was appropriate (completed follow-up or documented reason for no follow-up) or potentially inappropriate (no follow-up or no documented reason). Providers of a second patient group were contacted 5-6 days after imaging examinations to determine notification preferences. RESULTS: Among 43 patients in the first group, five (12%) received potentially inappropriate management. Reasons included patient loss to follow-up and provider failure to review imaging results, document known imaging findings, or communicate findings to providers outside the health system. Among 16 providers caring for patients in the second group, 33% were unaware of the findings, 75% preferred to be notified of abnormal findings via e-mail or EMR, 56% wanted an embedded hyperlink enabling immediate follow-up order entry, and only 25% had a system to monitor whether patients had completed ordered testing. CONCLUSIONS: One in eight patients did not receive potentially necessary follow-up care within 3 months of imaging findings of possible cancer. Automated notification of imaging findings and follow-up monitoring not only is desired by providers but can also address many of the reasons we found for inappropriate management.


Assuntos
Continuidade da Assistência ao Paciente , Diagnóstico por Imagem , Comunicação Interdisciplinar , Neoplasias/diagnóstico , Padrões de Prática Médica/normas , Humanos , Sistemas Computadorizados de Registros Médicos
10.
BMC Evol Biol ; 6: 33, 2006 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-16620379

RESUMO

BACKGROUND: Thrombospondins (TSPs) are evolutionarily-conserved, extracellular, calcium-binding glycoproteins with important roles in cell-extracellular matrix interactions, angiogenesis, synaptogenesis and connective tissue organisation. Five TSPs, designated TSP-1 through TSP-5, are encoded in the human genome. All but one have known roles in acquired or inherited human diseases. To further understand the roles of TSPs in human physiology and pathology, it would be advantageous to extend the repertoire of relevant vertebrate models. In general the zebrafish is proving an excellent model organism for vertebrate biology, therefore we set out to evaluate the status of TSPs in zebrafish and two species of pufferfish. RESULTS: We identified by bioinformatics that three fish species encode larger numbers of TSPs than vertebrates, yet all these sequences group as homologues of TSP-1 to -4. By phylogenomic analysis of neighboring genes, we uncovered that, in fish, a TSP-4-like sequence is encoded from the gene corresponding to the tetrapod TSP-5 gene. Thus, all TSP genes show conservation of synteny between fish and tetrapods. In the human genome, the TSP-1, TSP-3, TSP-4 and TSP-5 genes lie within paralogous regions that provide insight into the ancestral genomic context of vertebrate TSPs. CONCLUSION: A new model for TSP evolution in vertebrates is presented. The TSP-5 protein sequence has evolved rapidly from a TSP-4-like sequence as an innovation in the tetrapod lineage. TSP biology in fish is complicated by the presence of additional lineage- and species-specific TSP paralogues. These novel results give deeper insight into the evolution of TSPs in vertebrates and open new directions for understanding the physiological and pathological roles of TSP-4 and TSP-5 in humans.


Assuntos
Evolução Molecular , Peixes/genética , Filogenia , Trombospondinas/genética , Sequência de Aminoácidos , Animais , Mapeamento Cromossômico , Biologia Computacional , Humanos , Homologia de Sequência de Aminoácidos , Sintenia , Trombospondinas/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...